Doors and Dunnies

Back to Blog Articles
01 December 2014

We work a lot with architects to get doorways circulation areas, clear widths and latch side clearances correct under AS1428.1.  We also do a lot of work making sure accessible toilets are appropriate with circulation areas of pan, basin and shower, as well as fixtures and fittings in accordance with AS1428.1.

We work a lot with architects to get doorways circulation areas, clear widths and latch side clearances correct under AS1428.1.  We also do a lot of work making sure accessible toilets are appropriate with circulation areas of pan, basin and shower, as well as fixtures and fittings in accordance with AS1428.1.

So why when we come to the building site, that in some instances, many of these elements are incorrect?

In the rarest of instances we find that a few architects simply don’t apply AS1428.1 properly….some even use older versions of the code.  However more often than not there are design and construction co-ordination issues.

We often review CC drawings.  However sometimes design changes such as enlarging a room or re-positioning a riser adjacent certain doors or accessible toilet occur in the construction documentation, after our review.  Sometimes, these changes hurt AS1428.1 compliance and are not picked up.

In other situations, even though the construction documentation is fully compliant, the contractor’s work shop drawings may be imperfect based on an incorrect assumption or knowledge of AS1428.1.

My point is that the quality control within the project needs to be more rigorous and perhaps another review of documentation may be required as an added insurance.

I would also like to add one more point that I see cropping up on jobs.  In accessible toilets, wash basins are allowed to encroach into the pan circulation area by no more than 100mm, when the basin is in front of the pan.  It is important to note that no encroachment is allowed when the basin is at the side of the pan as shown below:

What is also important to note is that the basin projection from the rear wall cannot be less than 430mm as shown above.  In the marketplace, the best accessible basins have a 450mm projection.  Make sure this projection is designed into your accessible toilets to get the right internal dimensions.

David Goding

Contact us

Have a
Question?

Have a project or design that needs an expert accessibility consultant? The team at MGAC are ready to hear from you.

Our skilled consultants are specialists in the application of DDA, UD, Accessibility, and Human Movement related to Australian Standards, NCC and Safety in Design.

Fill out the contact form and one of our access consultants will be in contact within 48 hours. Alternatively, you can contact one of our offices directly.

Please complete the email form and we will come back to you as soon as possible. Alternatively you can contact us directly using the contact details on the right

Our Offices

Sydney
Studio 6, Level 1
56 Bowman Street
Pyrmont NSW, 2009
(02) 9692 9322
Melbourne
Unit 304, 87 Gladstone St
South Melbourne, VIC 3205
(03) 9690 0102
Brisbane
99 Kingfisher Road
Victoria Point
Brisbane QLD, 4165
0476 299 321
Perth
24 Mumford Place
Balcatta, Perth, WA, 6021
0414 576 891